3. RF燤odule燙onfiguration?/DIV>
3.1. Hands-on Programming Examples
For information about entering and exiting AT and Binary Command Modes, refer to the
Command Mode section [p16].
3.1.1. AT Command Example
To Send AT Commands (Using the Terminal tab of MaxStreams X-CTU Software)
Example: Both of the following examples change the modules destination address to 0x1A0D and
save the new address to non-volatile memory.
Method 1 (One line per command)
 
 
 
 
 
 
Send AT Command
 
 
System Response
 
 
 
+++
 
 
 
 
OK (Enter into Command Mode)
 
ATDT    
 
 
current Destination Address (Read)
 
ATDT1A0D
 
 
OK (Change destination address)
 
ATWR    
 
 
OK (Write to non-volatile memory)
 
ATCN    
 
 
OK (Exit Command Mode)
Method 2 (Multiple commands on one line)   
 
 
 
 
 
Send AT Command
 
 
System Response
 
 
 
+++
 
 
 
 
OK (Enter into Command Mode)
 
ATDT    
 
 
current Destination Address (Read)
 
ATDT1A0D,WR,CN
 
OK (Execute commands)
Note: In order to use a host PC and the X-CTU Software Terminal tab to send data to the module, PC
com port settings must match the baud, parity & stop bit parameters stored in the module.
Use the PC Settings tab to configure PC com port settings to match module parameter values.
3.1.2. Binary Command Example
To Send Binary Commands:
Example: Use binary commands to change the XStream Modules destination address to 0x1A0D
and save the new address to non-volatile memory.
1.   RT Command must be set to 1 in AT Command Mode to enable binary programming.
2.   Assert CMD (Pin 5 is driven high).
(Enter Binary Command Mode)
3.   Send Bytes (parameter bytes must be 2 bytes long):
 
 
 
 
 
 
00
 
 
(Send DT (Destination Address) Command)
 
 
0D
 
 
(Least significant byte of parameter bytes)   
 
 
1A
 
 
(Most significant byte of parameter bytes)   
 
 
08
 
 
(Send WR (Write) Command)
4.   De-assert CMD (Pin 5 is driven low)
(Exit Binary Command Mode)
 
Note:
  (pin 1) is de-asserted high when commands are being executed. Hardware flow control
must be disabled as
 will hold off parameter bytes.
MaxStreams X-CTU
Software facilitates
module programming.
To install, double-click
the setup_X-CTU.exe
file that is located on
the MaxStream CD &
on the Internet.
(www.maxstream.net)
牋牘?006燤axStream,營nc.燙onfidential燼nd燩roprietary?/DIV>
18?/DIV>
相关PDF资料
XIB-R BOARD INTERFACE RS232/485
ZMN2400HPDB BOARD ROUTER DEV ZIGBEE 100MW
ZMN24HPDK-B KIT DEV W/ZIGBEE ZMN2400HP
ZNI1000TC IC TEMP SENSOR NI1000 SOT23-3
02110102-000 SNSR TILT RATIO 60DEG 500MA FLNG
1-5209285-2 FOPC BOA 12DB FC/UPC BP SM
2-1693560-0 BOA 20DB LC/UPC BB
517SS16 MAGNETIC SENSORS BIPOLAR ICS
相关代理商/技术参数
XIB-R 功能描述:界面模块 RS-232/485 interface 24XStream 9XCite RoHS:否 制造商:4D Systems 产品:Serial Converters 通道/端口数量: 数据速率: 接口类型:USB, UART 工作电源电压:3.3 V, 5 V 最大工作温度:
XIB-U 功能描述:界面模块 USB interface board 24XStream 9XCite RoHS:否 制造商:4D Systems 产品:Serial Converters 通道/端口数量: 数据速率: 接口类型:USB, UART 工作电源电压:3.3 V, 5 V 最大工作温度:
XIC25040 制造商:XIC 功能描述:25040 24HR '6
XILINXPWR-079 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-080 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-081 功能描述:电源管理IC开发工具 Pwr Mgmt Eval Mod Xilinx RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-082 功能描述:电源管理IC开发工具 Pow Mgt Eval Mod for Xilinx FPGAs RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V
XILINXPWR-083 功能描述:电源管理IC开发工具 Pwr Mgmt Eval Mod Xilinx RoHS:否 制造商:Maxim Integrated 产品:Evaluation Kits 类型:Battery Management 工具用于评估:MAX17710GB 输入电压: 输出电压:1.8 V